Autoclave (Cylindrical Horizontal)

Applications:
Ferrotek is the most Reliable Autoclave for all applications requiring, total destruction of all living micro-organisms, in laboratories, hospitals, nursing homes, R & D labs, etc. It is used to sterilize equipment by subjecting them to high pressure saturated steam at 121° C for around 15-20 minutes.

Construction :-
° Triple walled with separate steam jacket and boiler.
° Inner chamber & steam jacket are made of heavy gauge S. S. sheet with leak proof argon arc
welding
° The sterilizer has single piece door made of thick Stainless Steel plate.
° All the sterilizer are hydraulically tested to withstand pressure upto 40 psi.
° Mounted on tubular steel frame with ground leveling screwed flanges.
° The space between outer wall and steam jacket is filled with glass wool to minimize the heat losses.

Model No. : FE-104

Steam Generator(Boiler)
° Made of heavy gauge Stainless Steel Sheet(304 grade).
” Fitted with flanged immersion type heaters at the back.
° Also fitted with Low Water Level Cutoff Device to protect the heaters from burning out dry.
° Complete with Water Level Indicator Water Inlet and Outlet Valves.

Pressure Control
The “PIEZOSTAT” (Pressure control device) is incorporated in the unit as it economizes on power consumption and reduces the frequent opening of the steam release valve and thus prevents the release of steam in the room, It cuts off the power supply to heaters when the set pressure is achieved and re-energies the heating elements when pressure falls below the set point.
Safety Door
Sterilizer has hinged self -locking single piece thick SS plate door and cannot be opened when under pressure. The self – locking device automatically disengages the piston mechanism when the sterilizer is under pressure.
Single Point Control
Complete sterilizing cycle is controlled from one point with the help of “Three way / Multiport Valve” fitted at front top. Easily readable jacket and chamber pressure on gauges mounted on the front top. A moisture trap is fitted in the chamber discharge line to absorb the condensate automatically to prevent moistening of the subject matter to be sterilized. Automatic Vacuum breaker is provided to break vacuum in case of formation of vacuum due to steam condensation.
Switch Box
Houses the PIEZOSTAT, Main Switch, Indicator Lamps, Relays etc. and mounted on the stand of the sterilizer for easy operation.
Optional Accessories
SS Trolley, Dig. Temp. Indicator cum Controller Temperature Recorder Timer with Alarm System, Door at the Back (Double Door)

MODEL NO.

INNER SIZE

DIA x DEPTH

CAPACITY

HEATER LOAD

FE-104/1

400 x 600 mm

16 x 24 inch

75 ltr.

6 kw

FE-104/2

300 x 1100 mm

16 x 44 inch

138 ltr.

9 kw

FE-104/3

500 x 900 mm

20 x 36 inch

176 ltr.

12 kw

FE-104/4

550 x 750 mm

22 x 30 inch

178 ltr.

12 kw

FE-104/5

500 x 1100 mm

20 x 44 inch

216 ltr.

12 kw

FE-104/6

500 x 1200 mm

20 x 48 inch

235 ltr.

12 kw

Sterilizing Pressure

1.2 kgf/cm2 (15psi) at 121 oC

Pressure Gauge

0-1.2 kgf/cm2 (30psi)

Operating Pressure

Up to 20 psi

Power Supply

3 phase, 440 volts AC